Louisville-tin-and-stove WOW254 Bedienungsanleitung

Stöbern Sie online oder laden Sie Bedienungsanleitung nach Grills Louisville-tin-and-stove WOW254 herunter. Louisville Tin and Stove WOW254 User Manual Benutzerhandbuch

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 29
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 0
- Do not store or use gasoline or other flammable vapors
and liquids in the vicinity of this or any other appliance.
- WHAT TO DO IF YOU SMELL GAS:
Do not try to light any appliance.
Do not touch any electrical switch; do not use any
phone in your building.
Immediately call your gas supplier from a neighbor’s
phone. Follow the gas supplier’s instructions.
If you cannot reach your gas supplier, call the
fire department.
- INSTALLATION AND SERVICE MUST BE PER-
FORMED BY A QUALIFIED INSTALLER,
SERVICE AGENCY OR THE GAS SUPPLIER.
WARNING: If the information in these instructions are
not followed exactly, a fire or explosion may result
causing property damage, personal injury or loss of life.
FAN-TYPE, DIRECT-VENT
THROUGH-THE-WALL
GAS HEATER
INSTALLATION AND
OPERATING INSTRUCTIONS
P/N 64920 / DECEMBER 2006
R
R
This appliance must be
connected to an electrical
ground.
WARNING:
CONNECT TO 115V ELECTRICAL
POWER SUPPLY.
DO NOT CONNECT TO 220V
POWER SUPPLY.
MODEL NUMBERS
NAT. GAS L.P. GAS
WOW253 WOW254
WOW403 WOW404
NOTE: Obstruction in the vent exhaust tube or air intake tube due to insects, small animals, debris,
etc. will prevent the heater from operating but DOES NOT constitute a warranty issue.
This unit is for residential installation only and is not approved for greenhouses, or environments
involving dusty, wet, corrosive, or explosive conditions. Installation and usage other than
residential applications will invalidate the warranty and may create unsafe conditions resulting in
property damage, personal injury or loss of life.
WARNING: Operation of this furnace without the factory installed vent system could result in Carbon Monox-
ide (CO) poisoning and possible death. For your safety, this furnace and the vent system must be inspected
before initial use and at least annually by a qualified service person.
This appliance may be installed in an aftermarket, permanently located, manufactured home (USA only) or
mobile home, where not prohibited by local codes. This appliance is only for use with the type of gas indicated
on the rating plate. This appliance is not convertible for use with other gases, unless a certified kit is used.
Installation, maintenance, service, troubleshooting and repairs must be performed by a qualified service agency.
MR./MRS. HOMEOWNER, DO NOT attempt any of these procedures yourself as this could expose you to
property damage, personal injury, or loss of life and will invalidate all warranties.
INSTALLER: Leave this manual with the
appliance.
CONSUMER: Retain this manual for future
reference.
Seitenansicht 0
1 2 3 4 5 6 ... 28 29

Inhaltsverzeichnis

Seite 1 - OPERATING INSTRUCTIONS

- Do not store or use gasoline or other flammable vaporsand liquids in the vicinity of this or any other appliance. - WHAT TO DO IF YOU SMELL GAS:

Seite 2 - CONTENTS

Page 10INSTALLING THROUGH A FRAME WALLNOTE: The WOW25 models will install between wall studs on 16” centers. The WOW40 will attach to a studon eithe

Seite 3

Page 11INSTALLING THROUGH A MASONRY WALLA.) At desired height, mark hole opening for yourmodel heater. (See Figure 11).B.) Before cutting, verify bot

Seite 4 - FIGURE 1

FOR YOUR SAFETY READ BEFORE OPERATINGWARNING: If you do not follow these instructions exactly, a fire or explosion may resultcausing property damage,

Seite 5 - IS NOT PERMITTED

NATURAL GAS WOW253 1.3 5 5 5 6 5 6 57 WOW403 5 4 5 5 5 5 56 5 6L.P. GAS WOW254 6 7 6 8 6 9 70 7 0 WOW404 6 6 6 8 6 8 69 7 0 MODEL 0 to

Seite 6 - CLEARANCES

Page 14GAS CONVERSIONThis heater is field convertible. Use only factory sup-plied, certified kits.Model ConversionNumber Description Kit No.WOW253 Co

Seite 7 - STEP 3 - LOCATE THERMOSTAT

WIRINGIF ANY OF THE ORIGINAL WIRE AS SUPPLIED WITH THE APPLIANCE MUST BE REPLACED, ITMUST BE REPLACED WITH A WIRE OF AT LEAST 105 DEGREE C T

Seite 8 - WINDOW INSTALLATION

WIND-O-WARM SEQUENCE OF OPERATIONSTEP #1) Thermostat calls for heat.2) Draft Inducer turns on.3) Pressure switch closes.4) Spark ignition begins.5) Ga

Seite 9 - WINDOW INSTALLATION - Cont’d

MAINTENANCE INSTRUCTIONS For correct and safe operation, keep heater and heater area clean. At regular intervals, turn control valveto OFF, let hea

Seite 10

Page 18TO REMOVE MAIN BURNERS FOR INSPECTION AND CLEANING:SERVICE MUST BE PERFORMED BY A QUALIFIED SERVICE AGENCYFIGURE 17WOW253 / WOW254 MODELS

Seite 11

TO REMOVE MAIN BURNERS FOR INSPECTION AND CLEANING:SERVICE MUST BE PERFORMED BY A QUALIFIED SERVICE AGENCYA.) Turn thermostat to “OFF” or lowest

Seite 12 - TO TURN OFF GAS TO APPLIANCE

Page 2INTRODUCTIONTHIS IS A GAS-FIRED, DRAFT INDUCED, POWER DEPENDENT, DIRECT VENT WALL FURNACE;THAT WILL OPERATE SAFELY AND PROVIDE AN EFFICIENT

Seite 13 - ORIFICING

Page 20SERVICE MUST BE PERFORMED BY AQUALIFIED SERVICE AGENCY.A.) Turn thermostat to “OFF” or lowest setting.B.) Allow heater to cool.C.) Turn off ele

Seite 14

TO REMOVE COMBUSTION TUBE ASSEMBLY FORINSPECTION, CLEANING AND REPLACEMENTSERVICE MUST BE PERFORMED BY AQUALIFIED SERVICE AGENCY.A.) Turn thermostat t

Seite 15 - P/N 91467 08/2005

# OF REASON FOR FLASHES INDICATION POSSIBLE CAUSES CORRECTIVE ACTION Slow Flash Normal operation,no call for heatFast Flash Normal operation,call fo

Seite 16

Page 23TROUBLE SHOOTING CHART SYMPTOM POSSIBLE CAUSES CORRECTIVE ACTION Flame too large 1. Defective operator section of valve. 1. Replace valve

Seite 17

Page 24MODEL NUMBERSNAT. GAS L.P. GASWOW253 WOW254FAN-TYPE, DIRECT-VENTTHROUGH-THE-WALL GAS HEATERPrices and specifications subject to change withou

Seite 18

Page 25MODEL NUMBER NAT. WOW253MODEL NUMBER L.P. WOW254REF. PARTLISTPART DESCRIPTION NO. NO. PRICEManifold 1 64501Manifold Gasket 2 64665Gas

Seite 19

Page 26MODEL NUMBERSNAT. GAS L.P. GASWOW403 WOW404Mr. Contractor, we only sell parts through our wholesalers, but the prices listed are for your con

Seite 20 - For WOW253 / WOW254

Page 27DECEMBER 2005HOW TO PROPERLY ORDER PARTS: In addition to part description and part number, please give model number, serialnumber, and type of

Seite 21 - For WOW403 / WOW404

Mr. Contractor, we only sell parts through our wholesalers, but the prices listed above are for your convenience. For promptparts service, contact th

Seite 22 - TROUBLE SHOOTING CHART

LIMITED WARRANTYLIMITED WARRANTYLIMITED WARRANTYLIMITED WARRANTYLIMITED WARRANTYThe Louisville Tin & Stove Co. warrants to the original use

Seite 23 - TROUBLE SHOOTING CHART

SAFETY RULESThe Direct Vent Gas Wall/Window Heater and its components meet all applicable safety standards when installed asdirected in this manual.

Seite 24 - THROUGH-THE-WALL GAS HEATER

Page 4INSTALLATIONWARNING: Failure to follow these instructions exactly may result in poor performance, property damage,personal injury, or loss of li

Seite 25 - MODEL NUMBER L.P. WOW254

Page 5FIGURE 2. VENT TERMINAL CLEARANCES V VENT TERMINAL X AIR SUPPLY INLET AREA WHERE TERMINAL IS NOT PERMIT

Seite 26 - THE-WALL GAS HEATER

Page 64. Allow 48” (122 cm) inches from outside rear of cabinet to any obstructions such as fences, walls, shrubs,trees, etc. (Consider outside appea

Seite 27 - WOW404

Page 7STEP 3 - LOCATE THERMOSTAT1. Thermostat must be installed in same room as heater.2. Locate thermostat on an inside wall approximately 5 feet {

Seite 28 - REPLACEMENT WIRING

E.) Center outer cabinet in window openingand slide in so bottom flange is flushagainst windowsill. Secure cabinet towindowsill through holes provide

Seite 29 - LIMITED WARRANTY

Page 9WINDOW INSTALLATION - Cont’d.H.) Using 3 #8 x 3/8” screws (provided), attach trimpanels to left and right flanges on outer cabinet.The 1/2”, 90

Verwandte Modelle: WOW403

Kommentare zu diesen Handbüchern